Feasibility Study on Using GFRP and Epoxy Resin Mix Waste Powder in Concrete to Partially Replace the Cement

Authors

  • Fatema Ali Hamed Muhanaa Al Shibli Civil and Environmental Engineering Department, College of Engineering, National University of Science and Technology, Oman
  • Afnan Hilal Hamed AL Sarmi Civil and Environmental Engineering Department, College of Engineering, National University of Science and Technology, Oman
  • Arwa Hamed Muhanna Mohammed Al Shibli Civil and Environmental Engineering Department, College of Engineering, National University of Science and Technology, Oman
  • N. Aravind Civil and Environmental Engineering Department, College of Engineering, National University of Science and Technology, Oman https://orcid.org/0000-0001-9403-5463
  • Eman Muhye Adeen Muhye Al Hatali Civil and Environmental Engineering Department, College of Engineering, National University of Science and Technology, Oman
  • Khadija Salim Abdullah Al Balushi Mechanical & Industrial Engineering Department, College of Engineering, National University of Science and Technology, Oman
  • Geetha Devi Mechanical & Industrial Engineering Department, College of Engineering, National University of Science and Technology, Oman

DOI:

https://doi.org/10.37256/sce.6120255866

Keywords:

GRE waste powder, experimental investigation, strength properties, control specimen

Abstract

Every day a huge quantity of glass fiber reinforced polymer (GFRP) and glass reinforced epoxy (GRE) waste powder is coming from the composite pipe industries in Oman. This powder is harmful to human beings and aquatic animals. Composite pipe manufacturing industries are struggling a lot with the disposal of waste GRE dust. At present, these GRE waste materials are buried under the ground without affecting the groundwater. Impervious layers are constructed to avoid seepage and protect the groundwater. Composite pipes manufacturing industries are spending huge amounts to save the environment from GRE waste disposal. In this experimental project, GRE waste is added to the concrete to partially replace cement with proportions such as 5%, 15% and 25%. Mechanical properties of concrete with and without GRE waste are investigated like compressive, split tensile strength and bending strength tests experimentally. Experimental results depict that the spilt tensile value of concrete with 5% GRE dust is 6.45% more when compared to the control specimen. Also, compressive and bending strengths of concrete with 5% GRE dust are not much affected and it is almost equal to the control specimen.

Downloads

Published

2025-02-12

How to Cite

(1)
Fatema Ali Hamed Muhanaa Al Shibli; Afnan Hilal Hamed AL Sarmi; Arwa Hamed Muhanna Mohammed Al Shibli; N. Aravind; Eman Muhye Adeen Muhye Al Hatali; Khadija Salim Abdullah Al Balushi; Geetha Devi. Feasibility Study on Using GFRP and Epoxy Resin Mix Waste Powder in Concrete to Partially Replace the Cement. SCE 2025, 6, 88-98.